5.0 MAINTENANCE AND TROUBLESHOOTING
A. CLEANING
Periodically, remove the cover from the power source and blow accumulated
dust and dirt from the air passages and interior components by using clean low
pressure air. The frequency of cleaning required depends upon the environment
in which the power source is used.
It is imperative that all air passages be kept as clean as possible in order to allow
adequate air flow to provide proper cooling.
After cleaning with low pressure air, check for and tighten any loose hardware,
including all electrical connections. Check for frayed and/or cracked insulation
on all power cables and replace if necessary.
B. INSPECTION AND SERVICE
Keep the power source dry, free of oil and grease, and protected at all times from
damage by hot metal and sparks.
C. FAN MOTOR
Keep the fan motor free of accumulated dust and lint.
D. TRANSFORMER
Other than periodically cleaning the dust and dirt from the transformer, no
maintenance is required. Ensure that only clean, dry, low pressure air is used.
E. WIRE FEEDER CONTROL CIRCUITS
These circuits are protected by two 10 amp circuit breakers mounted in the front
panel. If these open, the contactor and wire feeder will not operate.
F. OVER TEMPERATURE PROTECTION
If the power source reaches an abnormally high internal temperature, the
thermal protection will deenergize the contactor circuit, shutting down the power
source but leaving the cooling fan on. After the power source has cooled to a
safe level, the thermal protection will automatically reset. While de-energized,
the contactor and wire feeder cannot be operated.
G. TROUBLESHOOTING
If the power source is operating improperly, the following troubleshooting
information may be used to locate the source of the trouble.
Check the problem against the symptoms in the following troubleshooting guide
(Table 5-1.) The remedy for the problem may be quite simple. If the cause
cannot be quickly located, open up the unit and perform a simple visual
inspection of all the components and wiring. Check for proper terminal
connections, loose or burned wiring or components, blown fuses, bulged or
leaking capacitors, or any other sign of damage or discoloration.