SECTION 4 OPERATION
4.5 SPOOL-ON-GUN CONNECTION/OPERATION
The Migmaster 250 Plus is equipped with a built-in control for the ST-23A or MT-
250SG Spool Gun which operates via the amphenol control receptacle and the
front panel output receptacles.
To operate the unit an ST-23A or MT-250-SG, do the following:
A. Place the STD./Spool Gun selector toggle switch in the 250 Plus to its
Spool Gun position.
B. Connect the MT-250SG / ST-23A control cable amphenol to the receptacle
labeled CONTROL on the 250 Plus’s front panel.
C. If using an MT-250SG, connect the power cable directly to the (+) positive
Low Inductance output terminal.
If using a ST-23A, connect the gas/power cable to the power cable
adaptor (P/N 37301). Plug the adapter into the (+) positive Low Inductance
output terminal (see Section 3.5).
D. If using an MT-250SG, connect the gas hose directly to the R-33-FM
flowmeter regulator. Set the flow to 30 cfh.
If using an ST-23A, connect the gas hose from the power cable adapter
directly to the R-33-FM flowmeter regulator. Set the flow to 30 cfh.
E. Connect the 250 Plus’s WORK cable to the workpiece.
F. Set Migmaster 250 Plus voltage tap switches to RANGE and FINE
ADJUSTMENT VOLTAGE desired settings.
G.Turn on the Migmaster 250 Plus’s power switch and begin welding.
If the optional Spot/Stitch/Anti-Stick control module is installed, the MT-250SG
and the ST-23A gun may be operated using these optional features, see Section
4.6.
Figure 4.3 - Connecting Spool-On-Gun
ST-23A Requires
Power Cable Adapter 37301
To Connect to Front Panel
Twist Lock Receptacle
MT-250SG
Connects Directly to the
Migmaster 250Plus
Front Panel Power and Control
Receptacle