ESAB MultiPower 460 Pulse Betriebsanleitung Seite 11

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 28
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 10
11
SECTION 1 DESCRIPTION
6. PANEL/REMOTE SWITCH
With this switch in the PANEL position, output voltage in the CV mode and the
output current in the CC mode are controlled by adjusting the VOLTAGE/
CURRENT/TRIM knob on the power source control panel to the desired
output. In the REMOTE position, output is controlled using a remote control
device such as a wire feeder, hand control or foot control depending on the weld
process being used.
7. INDUCTANCE TRIM
This control is used only in the STANDARD MIG process mode and is
deactivated in the TIG, STICK and MIG PULSE mode.
Inductance is used to optimize short circuiting arc performance by changing the
current rise and fall time of each short circuit. This results in improved spatter
control, weld bead wetting and arc stability. The short circuiting Mig arc
performance will change from a high short circuit frequency, fast reacting arc,
to a lower short circuit frequency, soft and less spattering arc as the dial is
turned clockwise. The optimized arc performances will vary depending on
shielding gas, wire type and wire diameter. The operator can adjust this control
to optimize welding characteristics.
8. MIG STANDARD/PULSE SWITCH
This switch enables the Mig pulse operation mode. When this switch is in the
MIG PULSE position, the pulse parameters are determined by the WIRE TYPE
and WIRE DIAMETER position on the PULSE SELECTION switches.
9. PULSE SELECTION SWITCHES
WIRE TYPE
Use this switch to select the WIRE TYPE installed on the wire feeder. The
position of this switch and the WIRE DIAMETER switch selects the pulse
parameters to be used during welding in the Mig pulse mode.
WIRE DIAMETER
Use this switch to select the WIRE DIAMETER installed on the wire feeder. The
position of this switch and the WIRE TYPE switch selects the pulse parameters
to be used during welding in the Mig pulse mode.
Digital Meters
Amps/Volts/WFS
Power “ON”
Lamp
Temperature
Lamp
No Program
Out of Range
Lamp
WFS - IPM
Lamp
Amps
Lamp
Preset
Button
Weld Process
Switch
Inductance
Adjustment
Current
Voltage
Pulse Trim
Figure 3-1- Pulse Mig Control Panel
Pulse
Standard
Switch
Remote
Standard
Switch
Pulse
Wire Type
Pulse
Wire Diameter
Seitenansicht 10