5.3 Fan control
The power source has a time control that means that the fans continue to run for 6.5
minutes after welding has stopped, and the unit switches to energy-saving mode.
The fans start again when welding restarts.
The fans run at reduced speed for welding currents up to 110 A, and at full speed for
higher currents.
5.4 Overheating protection
The welding power source has overheating protection that operates if the
temperature becomes too high. When this occurs the welding current is interrupted
and a fault code is displayed on the control panel.
The overheating protection resets automatically when the temperature has fallen.
6 MAINTENANCE
Regular maintenance is important for safe, reliable operation.
CAUTION
All guarantee undertakings from the supplier cease to apply if the customer attempts any
work to rectify any faults in the product during the guarantee period.
Only those persons who have appropriate electrical knowledge (authorized
personnel) may remove the safety plates.
6.1 Inspection and cleaning
Power source
Check regularly that the welding power source is not clogged with dirt.
How often and which cleaning methods apply depend on: the welding process, arc
times, placement, and the surrounding environment. It is normally sufficient to blow
down the power source with dry compressed air (reduced pressure) once a year.
Clogged or blocked air inlets and outlets otherwise result in overheating.
Welding torch
The welding torch's wear parts should be cleaned and replaced at regular intervals in
order to achieve trouble-free welding.