Fault light will energize if input voltage goes below or above ±15% of units
input rating. The light will not turn OFF even when correct voltage is restored.
Reset by placing Powercut 650 power switch OFF and then ON again.
NOTE: When in LOCK-IN mode, the FAULT light will turn on during second
"trigger". This does not aect performance. Turn o.
•
E. Amber "FAULT" light ON.
Is the unit overheated?
("Fault" lights turns o
when Unit cools down.)
Yes No
Is air owing?
Duty cycle exceeded:
40% @ 40 A, 60% @ 30 A, Yes No
or 100% @ 22 A output
See Sect 5.1
Is input voltage within ±15% of units input rating?
Yes No
Adjustvoltage• Repairpowersource
Figure 5-5. Sequence of Operations