SECTION 3 INSTALLATION
Selecting the proper Inductance for a specific application and shield gas is
mostly a matter of personal preference. The Inductance setting will change the
crispness of the welding arc and change bead shape by affecting the weld pool
fluidity. Table 3.2 is a general guide to setting Inductance level.
Table 3.2 Recommended Output Inductance Tap Connections for Short-Arc Welding
Notes: The above chart shows the recommended output inductance tap connection for Mig Short Circuiting Transfer.
For Mig Spray Arc Transfer (stainless or carbon steel) - use low tap
For Flux Cored Wire (all types) - use low tap
NR - Not Recommended
* The best connection (high tap or low tap) depends on the specific welding application and personal preference.
Stainless Steel
Solid Wires
Helium/Argon
Based Shielded
Gases
CO2
Shielding Gas
All Wire Diameters .023" (0.6mm) .030" (0.8mm) .035" (0.9mm) .045" (1.2mm)
All Wire
Diameters
< 100 amps high tap high tap high tap high tap high tap low tap
125 amps high tap high or low* high or low* high or low* high or low* low tap
150 amps high tap N R low tap low tap low tap low tap
> 200 amps high tap N R N R low tap low tap low tap
Carbon Steels Solid Wires
Argon Based Shielding Gases
Welding
Current
Figure 3.9 Output Connections for DCEN (Straight Polarity) Operation
Figure 3.8 Output Connections for DCEP (Reverse Polarity) Operation